    VFD HS350 Series

    VFD HS360 & 361 Series

    VFD HS320 & 321 Series

    VFD HS710 Series

    VFD HS720 Series

    VFD HS721 Series

    VFD HS730Series

    VFD HS110 Series

    VFD HS280 & 281 Series

    VFD HS130 Series

    VFD HS230 Series

    VFD HS200 Series

    prev
    next

    VFD HS710 Series

    ■Excellent low frequency performance

    ■Wide voltage input

    ■Widely used

    ■Built-in automatic unit

    ■RS485 communication

    ■Comprehensive protection

    ■High security


    • Product profile
    • Product parameters
    • Data download
    • Optional Accessories

    NAH%JUMD3_K70{[{`X(S48M.png

    1.jpg

    海尚選型手冊電子文件-7.jpg


    HS710 iron case dimensions and weight

    Model

    A

    (mm)

    B

    (mm)

    H

    (mm)

    W

    (mm)

    D

    (mm)

    Mounting holes

    (mm)

    Net Weight (KG)

    Gross Weight (KG)

    The base

    Installation dimensions

    The peripheral size

    45KW  380V

    235

    485

    510

    320

    248

    8

    23

    25

    55KW  380V

    235

    485

    510

    320

    248

    8

    23

    25

    75KW  380V

    240

    635.5

    655

    377

    267

    8

    35

    40

    90KW  380V

    240

    635.5

    655

    377

    267

    8

    37

    42

    110KW 380V

    240

    635.5

    655

    377

    267

    8

    37

    42

    132KW  380V

    320

    730

    750

    495

    325

    10

    60

    70

    A

    160KW  380V

    320

    730

    750

    495

    325

    10

    63

    73

    A

    185KW  380V

    320

    730

    750

    495

    325

    10

    63

    73

    A

    200KW  380V

    460

    980

    1005

    632

    440

    13/16

    117

    137

    B

    220KW  380V

    460

    980

    1005

    632

    440

    13/16

    117

    137

    B

    250KW  380V

    460

    980

    1005

    632

    440

    13/16

    117

    137

    B

    280KW  380V

    460

    980

    1005

    632

    440

    13/16

    120

    140

    B

    315KW  380V

    600

    1210

    1250

    800

    450

    13/16

    174

    205

    C

    355KW  380V

    600

    1210

    1250

    800

    450

    13/16

    174

    205

    C

    400KW  380V

    600

    1210

    1250

    800

    450

    13/16

    179

    210

    C

    450KW  380V

    600

    1210

    1250

    800

    450

    13/16

    181

    212

    C

    500KW  380V

    600

    1210

    1250

    800

    450

    13/16

    181

    212

    C


    HS710 plastic case dimensions and weight

    Model

    A

    (mm)

    B

    (mm)

    H

    (mm)

    W

    (mm)

    D

    (mm)

    Mounting holes

    (mm)

    Net Weight (KG)

    Gross Weight (KG)

    The base

    Installation dimensions

    The peripheral size

    4.0KW 220V

    131

    229

    239

    140

    177

    5

    2.8

    3.2

    5.5KW 220V

    131

    229

    239

    140

    177

    5

    2.8

    3.2

    0.75KW 380V

    89

    140

    151

    100

    133

    5

    1.1

    1.3

    1.5KW  380V

    89

    140

    151

    100

    133

    5

    1.2

    1.4

    2.2KW  380V

    89

    140

    151

    100

    133

    5

    1.2

    1.4

    4.0KW  380V

    108

    203

    215

    120

    154

    5

    2.8

    3.2

    5.5KW  380V

    108

    203

    215

    120

    154

    5

    2.8

    3.3

    7.5KW  380V

    130

    237

    249

    143

    177

    5

    2.9

    3.4

    11KW  380V

    130

    237

    249

    143

    177

    5

    3.0

    3.7

    15KW  380V

    189

    306

    320

    205

    205

    6

    5.8

    6.5

    18.5KW  380V

    189

    306

    320

    205

    205

    6

    5.8

    6.7

    22KW  380V

    189

    306

    320

    205

    205

    6

    5.8

    6.8

    30KW  380V

    264

    388

    408

    288

    210

    6

    10.6

    12

    37KW  380V

    264

    388

    408

    288

    210

    6

    10.6

    12


    Dimensions of the HS710 base

    Base selection code

    Apply to power

    H(mm)

    W(mm)

    D(mm)

    A

    132KW--185KW

    670

    495

    400

    B

    200KW--280KW

    620

    635

    420

    C

    315KW--500KW

    550

    800

    450



    RZ]K901V]7HB_{HQ{{%DT[5.jpg 

    Basic configuration diagram

    Frequency converter wiring part is divided into the main loop and control loop. The user can lift the cover of the case to see the main loop terminal and the control loop terminal. The user must connect the wiring loop accurately according to the following.

    202101271657475112.jpg


    HS-710Technical specifications

    Project

    Technical specifications

    enter

    Rated voltage, frequency

    Three-phase  AC380V;50/60Hz

    Simplex  AC220V;50/60Hz

    Allowable voltage range

    Three-phase  AC360V~450V

    Simplex AC190V~250V

    Output

    Voltage

    0~460V

    0~260V

    frequency

    Low frequency mode:0~300Hz  High 

    frequency mode:0~3000Hz

    Overload capacity

    Model G:110% long-term 120% 22 minutes 150% 1 minute

    P type machine: 105% long-term 120% 8 minutes 150% 1 second

    way to control

    V/F control, advanced V/F control, V/F separation control, current vector contro

    Control characteristics

    Frequency setting resolution

    Analog input

    0.1% of maximum output frequency

    Digital setting

    0.01Hz

    Frequency accuracy

    Analog input

    Within 0.2% of the maximum output frequency

    Digital input

    Set within 0.01% of output frequency

    V/F control

    V/F curve

    Voltage frequency characteristic

     

    The reference frequency is arbitrarily set at 5~600Hz, and the multi-point V/F curve can be set arbitrarily. You can also choose constant torque, low-reduction torque 1, low-reduction torque 2, square torque and other fixed curves

    Torque boost

    Manual setting: 0.0~30.0% of rated output Automatic boost: automatically determine the boost torque according to the output current and combined with the motor parameters

    Automatic current limit and pressure limit

    Whether in the process of acceleration, deceleration or stable operation, it automatically detects the stator current and voltage of the motor, and suppresses it within the allowable range according to a unique algorithm, minimizing the possibility of system fault tripping

    Control characteristics

    Sensorless vector control

    Voltage frequency characteristics

    Automatically adjust the output voltage-frequency ratio according to motor parameters and unique algorithms

    Torque characteristics

    Starting torque:

    150% rated torque at 3.0Hz (VF control) 

    180% rated torque at 0.5Hz (no PG current vector control, magnetic flux vector control) 

    180% rated torque at 0.05Hz (with PG current vector control)

    Steady-state accuracy of operating speed: ≤±0.2% of rated synchronous speed

    Speed fluctuation: ≤±0.5% of rated synchronous speed

    Torque response: ≤50ms with PG vector control, without PG vector control, magnetic flux vector control ≤20ms

    Motor parameter self-determination

    Without any restriction, the automatic detection of parameters can be completed under the static and dynamic conditions of the motor to obtain the best control effect

    Current and voltage suppression

    Full-process current closed-loop control, completely avoid current impact, with perfect over-current and over-voltage suppression function

    Undervoltage suppression during operation

    Especially for users with low grid voltage and frequent fluctuations in grid voltage, the system can maintain the longest possible operating time according to the unique algorithm and residual energy distribution strategy even if the voltage is lower than the allowable voltage range.

    Typical function

    Multi-speed and swing frequency operation

    16-segment programmable multi-speed control, multiple operating modes are available. Swing frequency operation: preset frequency, center frequency can be adjusted, state memory and recovery after power failure.

    PID control RS485 communication

    Built-in PID controller (frequency can be preset). Standard configuration RS485 communication function, multiple communication protocols are optional, with linkage and synchronization control function.

    Frequency setting

    Analog input

    DC voltage 0~10V, DC current 0~20mA (upper and lower limits are optional)

    Digital input

    Operation panel setting, RS485 interface setting, UP/DW terminal control, also can be set in multiple combinations with analog input

    output signal

    Digital output

    2 OC outputs and 1 fault relay output (TA, TB, TC), up to 16 meaning options

    Analog output

    2 channels of analog signal output, the output range is flexibly set between 0~20mA or 0~10V, which can realize the output of physical quantities such as set frequency and output frequency

    Automatic voltage regulation operation

    Three modes of dynamic voltage regulation, static voltage regulation and unregulated voltage can be selected according to needs to obtain the most stable operation effect

    Acceleration and deceleration time setting

    0.1s~3600min can be set continuously, S-type and linear mode are optional

    brake

    Dynamic braking

    The initial voltage, hysteresis voltage and dynamic braking rate of dynamic braking are continuously adjustable

    DC braking

    Start frequency of DC braking at stop: 0.00~【F0.11】Upper limit frequency

    Braking time: 0.0~100.0s; braking current: 0.0%~150.0% of rated current

     

    Flux brake

    0~100 0: invalid

    Low noise operation

    The carrier frequency is continuously adjustable from 1.0KHz to 16.0KHz to minimize motor noise

    Speed tracking speed

    Restart function

    It can realize the smooth restart of the motor in operation and the restart function after instantaneous power failure

    counter

    One internal counter for easy system integration

    Run function

    Upper and lower limit frequency setting, frequency jump operation, reverse operation limit, slip frequency compensation, RS485 communication, frequency increase and decrease control, fault self-recovery operation, etc.


    Voltage

    Simplex

    Three-phase

    220V

    220V(240V)

    380V(415V)

    power(KW)

    Current(A)

    Current(A)

    Current(A)

    0.4

    2.3

    2.3

    -

    0.75

    4

    4

    2.1

    1.5

    7

    7

    3.8

    2.2

    9.6

    9.6

    5.1

    4

    17

    17

    8.5

    5.5

    25

    25

    13

    7.5

    -

    -

    16

    11

    -

    -

    24

    15

    -

    -

    32

    18.5

    -

    -

    36

    22

    -

    -

    44

    30

    -

    -

    58

    37

    -

    -

    70

    45

    -

    -

    90

    55

    -

    -

    110

    75

    -

    -

    152

    93

    -

    -

    172

    1 10

    -

    -

    205

    132

    -

    -

    253

    160

    -

    -

    304

    185

    -

    -

    340

    200

    -

    -

    380

    220

    -

    -

    426

    250

    -

    -

    465

    280

    -

    -

    520

    315

    -

    -

    585

    355

    -

    -

    650

    400

    -

    -

    725

    450

    -

    -

    820

    500

    -

    -

    935


    亚洲A∨精品一区二区三区,国产黄色在线视频,亚洲欧美色图,亚洲va中文字幕
  • <b id="03g94"><meter id="03g94"></meter></b>
  • <i id="03g94"></i>
    
    

    <thead id="03g94"></thead>
    <strike id="03g94"><label id="03g94"></label></strike>